Barnes White Iron Impellers- Salem Lakes, WI

catapult Barnes, Case Studies

MUNICIPALITY OVERVIEW: The Village of Salem Lakes, located in southeast Wisconsin, is a small rural community with a population of about 12,000 people. It’s municipality manages 25 pump stations. Of these 25, pump station 18 is the second largest station and is a triplex station with 30HP submersible non clog pumps. LIFT STATION DETAILS: The ductile iron vortex impellers of the pumps in station 18 were wearing out frequently due to abrasive particles in sewage. The worn-out impellers were catching …

Barnes SITHE – Whitinsville, MA

catapult Barnes, Case Studies

MUNICIPALITY OVERVIEW: The town of Sutton, Massachusetts is a small bedroom community of approximately 9000 residents. Originally settled in 1662, Whitinsville is a small rural community outside of Sutton with a population of 6,704 people located about 50 miles west of Boston. With support from Kats Pump Service, the contractor for the Sutton municipality, CP&S was able to replace an existing competitors’ product with a Sithe Chopper pump in July of 2017. The site of this install, the Whitinsville pump …

Barnes SITHE -Reduces clogging and saves service costs Cedar Hill. TX

catapult Barnes, Case Studies

Barnes Sithe submersible chopper pump prevents clogging by chopping rags, mop heads and diapers at Windsor lift station in Cedar Hill, TX SITE/LOCATION: Cedar Hill, TX The city sewer district is an urban wastewater district with 20 lift stations that serve a population of about 50,000. PROBLEM: The service team had to unclog non-clog pumps every 2-3 months. Different non-clog pump brands were tried, but frequency of clogging remained the same. Typically, rags and mop heads were clogging the pumps. …

Barnes SITHE – Reduced Clogging in Pataskala, OH

catapult Barnes, Case Studies

Barnes Sithe submersible chopper pump eliminates weekly clogging issues at Southwest Licking County’s lift station in Pataskala, OH. SITE/LOCATION: Pataskala, OH Southwest Licking County is a rural water and wastewater district that covers about 100 sq. miles. The wastewater treatment plant is designed to handle 2.5 million gallons per day. PROBLEM: Sources for this lift station are residential, including a trailer park, and several other lift stations. The sewage is pumped to the wastewater treatment plant. T-shirts, mop heads, ropes, …

Barnes Sithe Solves Clogging in Hamilton, AL

catapult Barnes, Case Studies

BARNES® SITHE – A cost saving solution to your clogging problems SITE/LOCATION: Hamilton, AL The city sewer district consists of 19 lift stations that cater a population of 6500. It’s treatment plant has a capacity of 1.5 million gallons per day. PROBLEM: The station has high solids content and the City had to pull out pumps monthly to unclog. Typically rags, hair, mop heads and debris were clogging the pumps. SOLUTION: Crane Pumps and Systems’ developed and provided a 7.5 …

Antique Deming Triplex Pump Operates 100 years after Installed

catapult Case Studies, Deming

Deming Pumps Built to Last SITE/LOCATION: Los Angeles, CA Located on the summit of Mount Wilson above Pasadena at an altitude of 5,715 feet, the Mt. Wilson Observatory is visible from much of the Los Angeles area. PROBLEM: A Deming Triplex pump was installed in 1911 at the Mount Wilson Observatory. It supplied the pressure for the fire hydrant system for an estimated 50 years until the 1960’s. In 2008, two volunteers performed routine maintenance repairs on the pump. Today …

sewer system restoration design

Sewer System Restoration Design Provides Advantages and Savings

catapult Barnes, Case Studies

The Barnes® Pressure Sewer Solution SITE/LOCATION: Lake Ariel, PA 3,800 home gated community in the Pocono Mountains of northeastern Pennsylvania. PROBLEM: An outdated, failing gravity-based sewer system with 26 failing duplex pumping stations. Raw sewage was leaking into yards, streets, and the lake. SOLUTION: Crane Pumps & Systems recommended a new pressure sewer system design utilizing KY Pipe hydraulic modeling software. The design eliminated all 26 of the failing stations and provided $80,000/year in electrical savings. The new system allows …

Burks® Vertical Multi-stage Pump Handles Tough Chemical Usage

catapult Case Studies

Burks® Vertical Multi-stage Pump Handles Tough Chemical Usage SITE/LOCATION: Greenville, SC Chemical wash process for the grease and lubricant industry. PROBLEM: Tiarco Chemical Division of Textile Rubber & Chemical Company, Inc. needed to install a new chemical wash process and required a pump that was resistant to chemicals, provided a constant low flow rate, and provided very low pulsations to prevent damage to the cleaning system. SOLUTION: Liquid Handling Equipment, a Crane Pumps & Systems’ channel partner, proposed a stainless …

Barnes SH Solves Clogging Problems at Cedar Cove Lift Station – Fishers, IN

catapult Barnes, Case Studies

Barnes SH Series SITE/LOCATION: Fishers, IN Duplex station serving an apartment complex and residential area. PROBLEM: Issues at the Cedar Cove lift station included outdated controls, wet well corrosion, failed valving and pump clogging. The biggest problem was the two 15HP three phase submersible pumps that were failing on average of once a month due to clogging or seal damage. SOLUTION: American Pump Repair & Service, Inc. (APRS), Crane Pumps & Systems channel partner, suggested to the municipality that they …

1972 Weinman Split Case Pumps Still Operating to Today’s Specifications

catapult Case Studies

Weinman® Split Case Pump SITE/LOCATION: Ithaca, NY Chilled water system for Cornell University’s Veterinary Medical Center. PROBLEM: Contractor work was being done inside Cornell University’s Veterinary Medical Center’s mechanical room when an object inadvertently fell on and cracked the upper case of one of three installed Weinman Split Case pump. SOLUTION: An exact replacement of the original pump, Weinman Model 8L2A Split Case pump. Features: Heavy castings absorb vibration and hydraulic noise for a smooth and quiet operation. Durable construction …