RV 1HP
2" 1HP Grinder Pump - Manual and Automatic
DISCHARGE: | 2” NPT |
LIQUID TEMPERATURE: | 104°F (40°C) Continuous |
VOLUTE: | Cast iron ASTM A-48, class 30 |
MOTOR HOUSING: | Cast iron ASTM A-48, class 30 |
SEAL PLATE: | Cast iron ASTM A-48, class 30 |
IMPELLERS: | Design: Semi-open, with pump out vanes on back side. Dynamically balanced, ISO G6.3. |
Material: Bronze | |
CUTTER PLATE: | Hardened 440C stainless steel Rockwell® C-55. |
CUTTER: | Hardened 440C stainless steel, Rockwell® C-55. |
SHAFT: | 416 Stainless steel |
SQUARE RINGS: | Buna-N |
HARDWARE: | 300 Series stainless steel |
PAINT: | Powder coat |
SEAL: | Design: Single mechanical |
Material:
| |
CORD LENGTH: | 20 ft. |
CORD: | Manual, CSA/UL Approved, 14/3 Type SJTOW |
UPPER BEARING: | Design: Single row, ball |
Lubrication: Oil | |
Load: Radial & thrust | |
LOWER BEARING: | Design: Single row, ball |
Lubrication Oil | |
Load: Radial & thrust | |
MOTOR: | Design: NEMA L-single phase torque curve, oil-filled, squirrel cage induction (includes overload protection in the motor) |
Insulation: Class F | |
SINGLE PHASE: | Capacitor start/capacitor run |
OPTIONAL EQUIPMENT: | Float |
MODEL NO - VOLT | RV101 - 115 | RV101A* - 115 | RV102 - 230 | RV102A* - 230 |
---|---|---|---|---|
PART NO | 145469 | 145469A | 145470 | 145470A |
HP | 1 | 1 | 1 | 1 |
VOLT | 115 | 115 | 230 | 230 |
PH/Hz | 1/60 | 1/60 | 1/60 | 1/60 |
RPM (nom) | 3450 | 3450 | 3450 | 3450 |
NEMA START CODE | G | G | G | G |
FULL LOAD AMPS | 12 | 12 | 6 | 6 |
LOCKED ROTOR AMPS | 43 | 43 | 31.4 | 31.4 |
CORD SIZE | 14/3 | 14/3 | 14/3 | 14/3 |
CORD TYPE | SJTOW | SJTOW | STJOW | STJOW |
CORD O.D. ± .02 (.5) in (mm) | 0.33 (8.38mm) | 0.33 (8.38mm) | 0.33 (8.38mm) | 0.33 (8.38mm) |
IMPORTANT
* NOTE: Models marked (*) are automatic and include Float IMPORTANT!
1.) PUMP MAY BE OPERATED “DRY” FOR EXTENDED PERIODS WITHOUT DAMAGE TO MOTOR AND/OR SEALS.
2.) INSTALLATIONS SUCH AS DECORATIVE FOUNTAINS OR WATER FEATURES PROVIDED FOR VISUAL ENJOYMENT MUST BE INSTALLED IN ACCORDANCE WITH THE NATIONAL ELECTRIC CODE ANSI/NFPA 70 AND/OR THE AUTHORITY HAVING JURISDICTION. THIS PUMP IS NOT INTENDED FOR USE IN SWIMMING POOLS, RECREATIONAL WATER PARKS, OR INSTALLATIONS IN WHICH HUMAN CONTACT WITH PUMPED MEDIA IS A COMMON OCCURRENCE.