Skip to main content

Crane Pumps & Systems

RV 1HP
2" 1HP Grinder Pump - Manual and Automatic
Rival_Grinder.jpg
Barnes_Logo_LightBlue.eps

DISCHARGE:

2” NPT

LIQUID TEMPERATURE:

104°F (40°C) Continuous

VOLUTE:

Cast iron ASTM A-48, class 30

MOTOR HOUSING:

Cast iron ASTM A-48, class 30

SEAL PLATE:

Cast iron ASTM A-48, class 30

IMPELLERS: 

Design: Semi-open, with pump out vanes on back side. Dynamically balanced, ISO G6.3.

Material: Bronze

CUTTER PLATE:

Hardened 440C stainless steel Rockwell® C-55.

CUTTER:

Hardened 440C stainless steel, Rockwell® C-55.

SHAFT:

416 Stainless steel

SQUARE RINGS:

Buna-N

HARDWARE:

300 Series stainless steel

PAINT:

Powder coat

SEAL:

Design: Single mechanical

Material:

  • Rotating Faces: Silicon-carbide

  • Stationary Faces: Silicon-carbide

  • Elastomer: Buna-N

  • Hardware: 300 Series stainless steel

CORD LENGTH:

20 ft.

CORD:

Manual, CSA/UL Approved, 14/3 Type SJTOW

UPPER BEARING: 

Design: Single row, ball

Lubrication: Oil

Load: Radial & thrust

LOWER BEARING:

Design: Single row, ball

Lubrication Oil

Load: Radial & thrust

MOTOR:

Design: NEMA L-single phase torque curve, oil-filled, squirrel cage induction (includes overload protection in the motor)

Insulation: Class F

SINGLE PHASE:

Capacitor start/capacitor run

OPTIONAL EQUIPMENT:

Float

Note

Choose your product model number on the right to filter content for your chosen pump.

MODEL NO - VOLT

RV101 - 115

RV101A* - 115

RV102 - 230

RV102A* - 230

PART NO

145469

145469A

145470

145470A

HP

1

1

1

1

VOLT

115

115

230

230

PH/Hz

1/60

1/60

1/60

1/60

RPM (nom)

3450

3450

3450

3450

NEMA START CODE

G

G

G

G

FULL LOAD AMPS

12

12

6

6

LOCKED ROTOR AMPS

43

43

31.4

31.4

CORD SIZE

14/3

14/3

14/3

14/3

CORD TYPE

SJTOW

SJTOW

STJOW

STJOW

CORD O.D. ± .02 (.5) in (mm)

0.33 (8.38mm)

0.33 (8.38mm)

0.33 (8.38mm)

0.33 (8.38mm)

IMPORTANT

* NOTE: Models marked (*) are automatic and include Float IMPORTANT!

1.) PUMP MAY BE OPERATED “DRY” FOR EXTENDED PERIODS WITHOUT DAMAGE TO MOTOR AND/OR SEALS.

2.) INSTALLATIONS SUCH AS DECORATIVE FOUNTAINS OR WATER FEATURES PROVIDED FOR VISUAL ENJOYMENT MUST BE INSTALLED IN ACCORDANCE WITH THE NATIONAL ELECTRIC CODE ANSI/NFPA 70 AND/OR THE AUTHORITY HAVING JURISDICTION. THIS PUMP IS NOT INTENDED FOR USE IN SWIMMING POOLS, RECREATIONAL WATER PARKS, OR INSTALLATIONS IN WHICH HUMAN CONTACT WITH PUMPED MEDIA IS A COMMON OCCURRENCE.